Code of Federal Regulations: Containing a Codification of Documents of General Applicability and Future Effect as of December 31, 1948, with Ancillaries and IndexDivision of the Federal Register, the National Archives, 1984 |
Dentro del libro
Resultados 1-5 de 34
Página 29
... weighing so as to insure accurate weights . All livestock scales shall be equipped with a type- registering weighbeam , a dial with a mechanical ticket printer , or a similar device which shall be used for printing or stamping the weight ...
... weighing so as to insure accurate weights . All livestock scales shall be equipped with a type- registering weighbeam , a dial with a mechanical ticket printer , or a similar device which shall be used for printing or stamping the weight ...
Página 30
... weighbeam . ( 2 ) The SR on a scale equipped with a balance indicator shall be the value of the minimum graduated interval on the weighbeam . ( e ) Tolerances . ( Applicable with re- spect to the performance or accuracy of scales ...
... weighbeam . ( 2 ) The SR on a scale equipped with a balance indicator shall be the value of the minimum graduated interval on the weighbeam . ( e ) Tolerances . ( Applicable with re- spect to the performance or accuracy of scales ...
Página 31
... weights necessary to move the weighbeam from a position of rest in the center of the trig loop to a posi- tion of rest either at the top or bottom of the trig loop . ( iii ) Shift test . A corner test conduct- ed with tests weights ...
... weights necessary to move the weighbeam from a position of rest in the center of the trig loop to a posi- tion of rest either at the top or bottom of the trig loop . ( iii ) Shift test . A corner test conduct- ed with tests weights ...
Página 32
... weights used to ascertain errors in the scale during the test should be removed and the scale re- stored to a zero - load balance . ( 5 ) Test procedure - dual weighing installations . Such installations usual- ly consisting of a weighbeam ...
... weights used to ascertain errors in the scale during the test should be removed and the scale re- stored to a zero - load balance . ( 5 ) Test procedure - dual weighing installations . Such installations usual- ly consisting of a weighbeam ...
Página 33
... weighbeam and / or dial , and the value of the minimum gradua- tions on weighbeam or dial face . ( 4 ) A statement of the maximum and minimum loads of livestock weighed . ( 5 ) Identification of the balance indi- cator manufacturer ...
... weighbeam and / or dial , and the value of the minimum gradua- tions on weighbeam or dial face . ( 4 ) A statement of the maximum and minimum loads of livestock weighed . ( 5 ) Identification of the balance indi- cator manufacturer ...
Otras ediciones - Ver todas
Términos y frases comunes
accordance actinobacillosis Administrator adulterated affected amended ance animal food anthrax application approved authorized beef carcasses casses cattle certificate cial circuit supervisor clean condemned consignee containers dealer demned devices disease edible products equipment estab export facilities Federal Federal Food feedlot filed handling human food inedible ingredients inspec inspected and passed Inspection Service inspector June 29 label lesions lishment live poultry livestock load lymph nodes market agency meat food products Meat Inspection Act ment notification offi official establishment operator oral otherwise packaging Packers and Stockyards paragraph passed for human percent person plant pork potassium nitrite poultry products prepared prescribed processing prod Program employee purposes quired records regulations removed revised rules of practice sausage scale sealed sodium specified spected statement stockyard owner subchapter Subpart swine Swine erysipelas tablishment thereof tion U.S. Department U.S. Suspect ucts unless viscera weighbeam weight