Página 20
... fire prevention requirements , and failure to adopt existing standards on grain explosion prevention are just a few ... extinguishers . Even standpipe systems and fire alarms are not 43 Hearings , p . 199 . 44 Hearings , p . 280 ...
... fire prevention requirements , and failure to adopt existing standards on grain explosion prevention are just a few ... extinguishers . Even standpipe systems and fire alarms are not 43 Hearings , p . 199 . 44 Hearings , p . 280 ...
Página 48
... fire department personnel arrived to find the warehouse burning and debris scattered around the area . Six injured ... fire extinguishers ; inadequate stairway railings ; improperly marked exists ; and excessive air hose pressure ...
... fire department personnel arrived to find the warehouse burning and debris scattered around the area . Six injured ... fire extinguishers ; inadequate stairway railings ; improperly marked exists ; and excessive air hose pressure ...
Página 81
... fire . ( i ) Drying processes conducted in buildings which are likely to ... fire or the development of excessive heat within the drier . ( k ) A maximum ... extinguishers and the hazards of the location . The use of the written ...
... fire . ( i ) Drying processes conducted in buildings which are likely to ... fire or the development of excessive heat within the drier . ( k ) A maximum ... extinguishers and the hazards of the location . The use of the written ...
Página 103
... fires " are fires which involve energized electrical equipment where the electrical nonconductivity of the extinguishing media is of importance . ( When electrical equipment is deenergized , extinguishers for Class A or B fires may be ...
... fires " are fires which involve energized electrical equipment where the electrical nonconductivity of the extinguishing media is of importance . ( When electrical equipment is deenergized , extinguishers for Class A or B fires may be ...
Página 104
... fire and discharges water over the fire area . NOTE : The design and installation of water supply facilities such as gravity tanks , fire pumps , reservoirs , or ... FIRE SUPPRESSION EQUIPMENT § 1910.157 Portable fire extinguishers . 104.
... fire and discharges water over the fire area . NOTE : The design and installation of water supply facilities such as gravity tanks , fire pumps , reservoirs , or ... FIRE SUPPRESSION EQUIPMENT § 1910.157 Portable fire extinguishers . 104.
Otras ediciones - Ver todas
Términos y frases comunes
agencies air pollution alarm approved areas belt bins bucket elevator building building or structure cause citation Class combustible Commission compliance conveyor designed devices drier dust collection system Dust Explosions electrical equipment employees exit Federal FGIS fire extinguishers Fire Protection fires and explosions flammable floor fumigant grain dryer grain dust grain elevator explosions grain elevator industry grain elevator operators grain handling facilities grain storage headhouse health standards Hearings hose hydrostatic test inches injuries inspection installed Iowa State University loading located maintenance manlift mill National Electrical Code Nebr NFPA occupational safety OSHA paragraph particulate matter percent opacity personnel pressure prevent promulgated standards proposed standards railcar regulations requirements safety and health sampling Secretary of Health silos sparks sprinkler standards of performance standpipe subpart subsection tion U.S. Department United States Code unloading station violations visible emissions welding Welfare Workmen's Compensation