A Staff Report on the Oversight of the Occupational Safety and Health Administration with Respect to Grain Elevator Fires and ExplosionsU.S. Government Printing Office, 1980 - 151 páginas |
Dentro del libro
Resultados 1-5 de 10
Página 48
... of fire extinguishers ; inadequate stairway railings ; improperly marked exists ; and excessive air hose pressure . According to OSHA documents , corrective actions were taken . SUNSHINE MILLS , INC . Sunshine Mills , Inc. , 48.
... of fire extinguishers ; inadequate stairway railings ; improperly marked exists ; and excessive air hose pressure . According to OSHA documents , corrective actions were taken . SUNSHINE MILLS , INC . Sunshine Mills , Inc. , 48.
Página 104
... hose . ) ( 2 ) Class II : For use primarily by the building occupants until the arrival of the fire department ( small hose ) . ( 3 ) Class III : For use by either fire departments and those trained in handling heavy hose streams or by ...
... hose . ) ( 2 ) Class II : For use primarily by the building occupants until the arrival of the fire department ( small hose ) . ( 3 ) Class III : For use by either fire departments and those trained in handling heavy hose streams or by ...
Página 108
... hose , a hydrostratic test shall be performed on the hose with its couplings ( but without the discharge nozzle ) at the test interval specified for the unit on which the hose is installed . ( vi ) The test pressure for dry chemical and ...
... hose , a hydrostratic test shall be performed on the hose with its couplings ( but without the discharge nozzle ) at the test interval specified for the unit on which the hose is installed . ( vi ) The test pressure for dry chemical and ...
Página 109
... hose systems . ( a ) General requirements— ( 1 ) Application . Where standpipe and hose systems are provided they shall meet the design requirements of the National Fire Pro- tection Association's Standard for the Installation of ...
... hose systems . ( a ) General requirements— ( 1 ) Application . Where standpipe and hose systems are provided they shall meet the design requirements of the National Fire Pro- tection Association's Standard for the Installation of ...
Página 110
... hose coupling shall be equipped with an approved automatic drip , arranged to discharge to a proper place . ( vii ) Hose connections shall be approved type and shall be equipped with standard caps , properly secured and arranged for ...
... hose coupling shall be equipped with an approved automatic drip , arranged to discharge to a proper place . ( vii ) Hose connections shall be approved type and shall be equipped with standard caps , properly secured and arranged for ...
Otras ediciones - Ver todas
Términos y frases comunes
agencies air pollution alarm approved areas belt bins bucket elevator building building or structure cause citation Class combustible Commission compliance conveyor designed devices drier dust collection system Dust Explosions electrical equipment employees exit Federal FGIS fire extinguishers Fire Protection fires and explosions flammable floor fumigant grain dryer grain dust grain elevator explosions grain elevator industry grain elevator operators grain handling facilities grain storage headhouse health standards Hearings hose hydrostatic test inches injuries inspection installed Iowa State University loading located maintenance manlift mill National Electrical Code Nebr NFPA occupational safety OSHA paragraph particulate matter percent opacity personnel pressure prevent promulgated standards proposed standards railcar regulations requirements safety and health sampling Secretary of Health silos sparks sprinkler standards of performance standpipe subpart subsection tion U.S. Department United States Code unloading station violations visible emissions welding Welfare Workmen's Compensation